Here is a full list of advanced settings (parameters) for the ZEN14 Double Outdoor Plug:
LED Indicator
Parameter 1: Decide how the LED indicator behaves depending on the on/off status of the plug. The LED indicator will flash twice to confirm a setting has been changed.
Values:
0 – LED indicator is on when the plug is on, LED indicator is off when the plug is off (default)
1 – LED indicator is on when the plug is off, LED indicator is off when the plug is on
2 – LED indicator is always off
Size: 1 byte dec
NOTE: Click the Z-Wave button 6 times quickly to toggle between the values of this parameter manually from the device.
Parameter 7: Set the brightness level of the LED indicator.
Values:
0 – high
1 – medium
2 – low (default)
Size: 1 byte dec
NOTE: Click the Z-Wave button 8 times quickly to toggle between the values of this parameter manually from the device.
Auto-off Timer
Parameter 2: Use this parameter to set the auto turn-off timer for Outlet 1: the time after which you want Outlet 1 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes.
Values: 0 – timer disabled (default); 1-65535 (minutes).
Size: 4 byte dec
Parameter 3: Use this parameter to set the auto turn-off timer for Outlet 2: the time after which you want Outlet 2 to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes.
Values: 0 – timer disabled (default); 1-65535 (minutes).
Size: 4 byte dec
Auto-on Timer
Parameter 4: Use this parameter to set the auto turn-on timer for Outlet 1: the time after which you want Outlet 1 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes.
Values: 0 – timer disabled (default); 1-65535 (minutes).
Size: 4 byte dec
Parameter 5: Use this parameter to set the auto turn-on timer for Outlet 2: the time after which you want Outlet 2 to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes.
Values: 0 – timer disabled (default); 1-65535 (minutes).
Size: 4 byte dec
On/Off Status Recovery After Power Failure
Parameter 6: Choose the recovery state for your Double Outdoor Plug if a power outage occurs.
Values:
0 – both outlets on the plug automatically turn OFF once power is restored (it ignores the status prior to power outage)
1 – both outlets on the plug automatically turn ON once power is restored (it ignores the status prior to the power outage)
2 – both outlets on the plug remember and restore the status prior to the power outage (default)
Size: 1 byte dec
NOTE: Click the Z-Wave button 10 times quickly to toggle between the values of this parameter manually from the device.
Z-Wave Button Control
Parameter 8: Choose if you want to use the physical Z-Wave button on the plug to turn the outlets on or off manually or if you want to disable this function. If this parameter is set to 0 (disabled), you will only be able to turn the outlet on or off remotely using your Z-Wave hub.
Values: 0 – manual control disabled; 1 – manual control enabled (default).
Size: 1 byte dec
Manual Control
1 x Z-Wave button press: turn Left output ON or OFF
2 x Z-Wave button press: turn Right output ON or OFF
3 x Z-Wave button press: inclusion or exclusion
6 x Z-Wave button press: toggle between Parameter 1 (LED Indicator Control) settings
8 x Z-Wave button press: toggle between Parameter 7 (LED Brightness) settings
10 x Z-Wave button press: toggle between Parameter 6 (On/Off Status Recovery After Power Failure) settings
Factory Reset: click the Z-Wave button twice and hold it the third time for 10 seconds. The LED indicator will flash green 3 times to confirm a successful reset.
Association Groups
The Outdoor Plug supports Group 1 for Lifeline communication and Group 2 with up to 5 devices for basic on/off control. This device will send a Basic Set command to Group 2 whenever it changes its on/off status.
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
COMMAND_CLASS_SWITCH_BINARY_V2,
COMMAND_CLASS_CONFIGURATION_V4,
COMMAND_CLASS_ASSOCIATION_V3,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V4
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION_V2,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_INDICATOR_V3,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
How to Access the Advanced Settings:
SmartThings
Hubitat
Home Assistant
If you'd like to update your ZEN14 Double Outdoor Plug, please register your device here. Once registered, you'll have access to the firmware updates. Don't forget to double check the model number and current firmware version before installing new firmware. Questions? Reach out to us!