Here is a full list of advanced settings (parameters) for the ZEN74 Toggle Dimmer 800LR :
On/Off Toggle Orientation
Parameter 1: Choose if you want to turn the light on or turn the light off when you toggle up the switch.
Values: 0 – Toggle up turns the light on, toggle down turns it off (default); 1 – Toggle up turns the light off, toggle down turns it on; 2 – Toggle any direction to turn the light on/off (change state).
Size: 1 byte dec
Auto Turn-Off Timer
Parameter 3: Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on).
Values: 0 – timer disabled (default); 1 – 65535 (minutes).
Size: 4 byte dec
Auto Turn-On Timer
Parameter 5: Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off).
Values: 0 – timer disabled (default); 1 – 65535 (minutes).
Size: 4 byte dec
On Off Status After Power Failure
Parameter 8: Set the on off status for the switch after power failure.
Values: 0 – forced to OFF (regardless of state prior to power outage); 1 – forced to ON (regardless of state prior to power outage); 2 – remembers and restores on/off status after power failure (default)
Size: 1 byte dec
Ramp Rate Control
Parameter 9: Adjust the "on" (fade-in) ramp rate for your dimmer when it's operated physically from the toggle. Values correspond to the number of seconds it take for the dimmer to reach full or max brightness.
Values: 1 – 99 (seconds). 0 – instant on. Default: 0.
Size: 1 byte dec
Parameter 27: Adjust the "off" (fade-out) ramp rate for your dimmer when it's operated physically from the toggle. Values correspond to the number of seconds it take for the dimmer to turn off from full or max brightness.
Values: 1 – 99 (seconds). 0 – instant off. Default: 2.
Size: 1 byte dec
Parameter 28: Adjust the "on" (fade-in) ramp rate for your dimmer when it's operated via Z-Wave from your hub. Values correspond to the number of seconds it take for the dimmer to reach full or max brightness.
Values: 1 – 99 (seconds). 0 – instant on. 255 – match physical ramp rate (set in parameter 9). Default: 255.
Size: 1 byte dec
Parameter 29: Adjust the "off" (fade-out) ramp rate for your dimmer when it's operated via Z-Wave from your hub. Values correspond to the number of seconds it take for the dimmer to turn off from full or max brightness.
Values: 1 – 99 (seconds). 0 – instant off. 255 – match physical ramp rate (set in parameter 27). Default: 255.
Size: 1 byte dec
Minimum and Maximum Brightness
Parameter 10: Set the minimum brightness level (in %) for your dimmer. You won’t be able to dim the light below the set value.
Values: 1 – 99 (%). Default: 1.
Size: 1 byte dec
Parameter 11: Set the maximum brightness level (in %) for your dimmer. You won’t be able to add brightness to the light beyond the set value. Note: if Parameter 12 is set to value 0, Parameter 11 is automatically disabled.
Values: 1 – 99 (%). Default: 99.
Size: 1 byte dec
Double Tap and Single Tap Behavior
Parameter 12: Choose what you'd like the dimmer to do when you double-tap the toggle up.
Values: 0 – the light will turn on to full brightness (default); 1 – the light will turn on to the custom brightness level set in parameter 18; 2 – the light will turn on to the maximum brightness level set in Parameter 11; 3 – double tap disabled.
Size: 1 byte dec
Parameter 25: Choose what you'd like the dimmer to do when you tap the toggle up once.
Values: 0 – the light will turn on to the last brightness level (default); 1 – the light will turn on to the custom brightness level set in parameter 18; 2 – the light will turn on to the maximum brightness level set in Parameter 11; 3 – the light will turn on to full brightness.
Size: 1 byte dec
Enable/Disable Scene Control
Parameter 13: Enable or disable scene control functionality for quick double tap triggers.
Values: 0 – scene control disabled (default). 1 – scene control enabled.
Size: 1 byte dec
Smart Bulb Mode: Enable/Disable Toggle / Z-Wave Control
Parameter 15: Enable or disable on/off control from the toggle (aka disable the relay). If disabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available from the toggle.
Values: 0 – physical toggle control disabled. 1 – physical toggle control enabled (default). 2 – physical toggle and Z-Wave control disabled. NOTE: hold the toggle up for 10 seconds until the LED indicator starts blinking, then within 2 seconds, toggle the switch up 5 times quickly to change this mode. The LED indicator will stay solid green for 3 seconds to confirm the change.
Size: 1 byte dec
Parameter 20: Choose how you'd like the dimmer to report when the toggle is tapped up/down or held and physical / Z-Wave control is enabled or disabled.
Values: 0 – send basic set report for each brightness level to hub when physical / Z-Wave control is disabled for physical dimming when the toggle is manually tapped/ held; report final brightness level only (basic set report) for physical dimming when the toggle is manually tapped/ held and physical / Z-Wave control is enabled; always report final brightness level only (via multilevel reports) for Z-Wave control regardless of the physical / Z-Wave control mode. 1 – report final brightness level only for physical dimming, regardless of the physical / Z-Wave control mode. 2 – send multilevel report for each brightness level to hub when physical / Z-Wave control is disabled for physical dimming when the toggle is manually tapped/ held; report final brightness level only (multilevel report) for physical dimming when the toggle is manually tapped/ held and physical / Z-Wave control is enabled; always report final brightness level only (via multilevel reports) for Z-Wave control regardless of the physical / Z-Wave control mode. Default: 2.
Size: 1 byte dec
Parameter 21: Set reporting behavior for disabled physical control.
Values: 0 – switch reports on/off status and changes LED indicator state even if physical and Z-Wave control is disabled (default). 1 – switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled.
Size: 1 byte dec
Physical Dimming Speed
Parameter 16: Set the time it takes to get from 0% to 100% brightness when pressing and holding the toggle (physical dimming). The number entered as value corresponds to the number of seconds.
Values: 1 – 99 (seconds). Default: 5.
Size: 1 byte dec
Remote Dimming Speed
Parameter 30: Set the duration for multilevel commands sent to devices associated with the dimmer in Group 3 for smooth remote dimming experience.
Values: 1 – 99 (seconds). Default: 5.
Size: 1 byte dec
Custom Brightness Level On
Parameter 18: Set the custom brightness level (instead of the last set brightness level) you want the dimmer to come on to when you single tap or double tap the toggle up (see parameters 12 and 25).
Values: 0 – last brightness level (default); 1 – 99 (%) for custom brightness level.
Size: 1 byte dec
Night Light Mode
Parameter 22: Set the brightness level the dimmer will turn on to when off and when the toggle is held DOWN for 2.5-3 seconds.
Values: 0 – feature disabled; 1 – 99 (%). Default: 20.
Size: 1 byte dec
Enable/Disable Programming on the Toggle
Parameter 26: Enable or disable programming functionality on the toggle (physical taps). If this setting is disabled, then inclusion, exclusion, smart bulb mode no longer work when dimmer is toggled in its usual sequence (factory reset and scene control will still work) - that means you can now use triple-tap triggers on the dimmer for scenes and remote control of other devices.
Values: 0 – programming enabled (default). 1 – programming disabled.
Size: 1 byte dec
Enable/Disable LED Indicator for Setting Changes
Parameter 32: Choose if you want the LED indicators to flash whenever a parameter (setting) is adjusted on the device to confirm the change. Disable this feature if you're using the LED indicators in automations.
Values:
0 – LED indicators flash to confirm a setting change (default)
1 - LED indicators don't flash if a setting is changed
Size: 1 byte dec
MANUAL CONTROL
Toggle Up:
1 x tap: load on; Scene 1, attribute 00
2 x tap: Scene 1, attribute 03
3 x tap: enter inclusion (pairing) mode (only if the switch is not included to the hub); Scene 1, attribute 04
4 x tap: Scene 1, attribute 05
5 x tap: Scene 1, attribute 06
held: increase brightness, Scene 1, attribute 01
released: Scene 1, attribute 02
Toggle Down:
1 x tap: load off; Scene 2, attribute 00
2 x tap: Scene 2, attribute 03
3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04
4 x tap: Scene 2, attribute 05
5 x tap: Scene 2, attribute 06
held: decrease brightness, Scene 2, attribute 01
released: Scene 2, attribute 02
held for 10 seconds (LED indicator starts blinking): enter the setting menu >> 5 x tap down for factory reset; 5 x tap up to change LED bulb mode (see parameter 11); 2 x tap down to enable the range test tool.
How to access advanced settings for the ZEN74 Toggle Dimmer on your hub:
The ZEN74 800LR Toggle Switch supports the following command classes:
- Z-Wave Plus Info V2
- Security 2 V1
- Supervision V1
- Transport Service V2
- Basic V2
- Association V3
- Association Group Information V3
- Multi Channel Association V3
- Version V3
- Manufacturer Specific V2
- Device Reset Locally V1
- Power Level V1
- Indicator V3
- Firmware Update Meta Data V5
- Configuration V4
- Central Scene V3
- Switch Multilevel V4