Here is a full list of advanced settings (parameters) for the ZSE43 XS Tilt | Shock Sensor:
LED Indicator
Parameter 1: Turn the LED indicator for open/close or vibration/no vibration status change on or off.
Values: 0 – LED indicator won’t blink when the sensor’s either status is changed; 1 – LED indicator will blink only when the sensor’s status is changed for vibration/no vibration; 2 – LED indicator will blink only when the sensor’s status is changed for open/close; 3 – LED indicator will blink when any of the sensors changes status (default).
Size: 1 byte dec
Battery Reporting
Parameter 2: Set the threshold for battery reporting.
Values: 1-50 (%). Default: 5
Size: 1 byte dec
Parameter 3: Decide when the sensor should report low battery to the hub.
Values: 10-50 (% battery life). Default: 20
Size: 1 byte dec
Shock Sensor Sensitivity
Parameter 4: Set the vibration sensor's level of sensitivity.
Values: 0 – highest level of sensitivity, will report the recorded vibration immediately (default); 1 – medium level of sensitivity, will report only if the vibration is recorded for 1.5 seconds or longer, it will keep reporting vibration for 2 more seconds after the last recorded activity; 2 – lowest level of sensitivity, will report only if the vibration is recorded for 2.5 seconds or longer, it will keep reporting vibration for 3 more seconds after the last recorded activity.
Size: 1 byte dec
Tilt Sensor Group 2 Association Commands
Parameter 5: Set the delay for the ON basic set command to be sent to the devices associated in Group 2 after the door is open.
Values: 0-3600 (seconds). Default: 0 (no delay).
Size: 4 byte dec
Parameter 6: Set the delay for the OFF basic set command to be sent to the devices associated in Group 2 after the door is closed.
Values: 0-3600 (seconds). Default: 0 (no delay).
Size: 4 byte dec
Parameter 8: Decide what type of Basic Set commands are sent to devices associated in Group 2.
Values: 0 – all Basic Set commands to Group 2 disabled; 1 – only Basic Set ON commands to Group 2 enabled; 2 – only Basic Set OFF commands to Group 2 enabled; 3 – both Basic Set commands (for on and off) to Group 2 enabled (default).
Size: 1 byte dec
Shock Sensor Group 3 Association Commands
Parameter 9: Decide what type of Basic Set commands are sent to devices associated in Group 3.
Values: 0 – all Basic Set commands to Group 3 disabled; 1 – only Basic Set ON commands to Group 3 enabled; 2 – only Basic Set OFF commands to Group 3 enabled; 3 – both Basic Set commands (for on and off) to Group 3 enabled (default).
Size: 1 byte dec
Disable Tilt or Shock Sensor
Parameter 7: Decide if you'd like to keep both tilt and shock sensors enabled or if you'd like to disable one of them.
Values: 0 – only tilt sensor enabled; 1 – only shock sensor enabled; 2 – both sensors enabled (default).
Size: 1 byte dec
ASSOCIATIONS:
Group 1: Lifeline to hub
Group 2: Basic set for open / close (tilt sensor)
Group 3: Basic set for vibration / no vibration (shock sensor)
Remember to click the Z-Wave button 4 times quickly to wake the sensor up after updating the settings. Your Tilt | Shock Sensor can be updated via OTA firmware updates. You can access all firmware files here after you register your product and create an account here. Questions? Just reach out to our tech support team.