Here is a full list of advanced settings (parameters) for the ZSE43 XS Tilt | Shock Sensor:
LED Indicator
Parameter 1: Decide if you want the LED indicator to blink when open/close tilt and/or vibration status changes.
Values: 0 – LED doesn't blink on status change; 1 – LED blinks on for vibration status change; 2 – LED blinks on for tilt status change; 3 – LED blinks on for vibration or tilt status change. Default: 3.
Size: 1 byte dec
Battery Reporting Threshold
Parameter 2: Set the threshold for battery reporting in % changes.
Values: 1-50 (%). Default: 5.
Size: 1 byte dec
Low Battery Report
Parameter 3: Which % level should the device report low battery to the hub.
Values: 10-50 (% battery life). Default: 20.
Size: 1 byte dec
Vibration Sensor Sensitivity
Parameter 4: Set the vibration sensor's level of sensitivity.
Values: 0 – highest level of sensitivity, will report the recorded vibration immediately; 1 – medium level of sensitivity, will report only if the vibration is recorded for 1.5 seconds or longer, it will keep reporting vibration for 2 more seconds after the last recorded activity; 2 – lowest level of sensitivity, will report only if the vibration is recorded for 2.5 seconds or longer, it will keep reporting vibration for 3 more seconds after the last recorded activity. Default: 0.
Size: 1 byte dec
ON Basic Set Reporting Delay to Group 2
Parameter 5: Set the delay for the ON basic set command to be sent to the devices associated in Group 2 after the door is open.
Values: 0-3600 (seconds). Default: 0 (no delay).
Size: 4 byte dec
OFF Basic Set Reporting Delay to Group 2
Parameter 6: Set the delay for the OFF basic set command to be sent to the devices associated in Group 2 after the door is closed.
Values: 0-3600 (seconds). Default: 0 (no delay).
Size: 4 byte dec
Disable Tilt or Vibration Sensor
Parameter 7: Decide if you'd like to disable the vibration (0) or tilt sensor (1) or keep both enabled (2).
Values: 0 – only tilt sensor enabled; 1 – only shock sensor enabled; 2 – both sensors enabled. Default: 2.
Size: 1 byte dec
Tilt Sensor Basic Set Commands
Parameter 8: Decide what type of Basic Set commands are sent to devices in Group 2 when tilt sensor is triggered (expert users only).
Values: 0 – all Basic Set commands to Group 2 disabled; 1 – only Basic Set ON commands to Group 2 enabled; 2 – only Basic Set OFF commands to Group 2 enabled; 3 – both Basic Set commands (for on and off) to Group 2 enabled. Default: 3.
Size: 1 byte dec
Vibration Sensor Basic Set Commands
Parameter 9: Decide what type of Basic Set commands are sent to devices in Group 3 when vibration sensor is triggered (expert users only).
Values: 0 – all Basic Set commands to Group 3 disabled; 1 – only Basic Set ON commands to Group 3 enabled; 2 – only Basic Set OFF commands to Group 3 enabled; 3 – both Basic Set commands (for on and off) to Group 3 enabled. Default: 3.
Size: 1 byte dec
Parameters 10-17 are available on Hardware VER 3.0 and Firmware 3.0 and up only. Hardware 1.0 and 2.0 units cannot update to 3.0 firmware:
Shock Clear Delay
Parameter 10: The amount of time the device waits to send a shock/vibration clear notification after the last shock event is detected.
Values: 1-3600 seconds. Default: 3.
Size: 1 byte dec
Tilt Open / Close Orientation
Parameter 11: Decide whether the tilt sensor reports closed (0) or open (1) in the default position (not tilted).
Values: 0 – Normally closed; 1 – Normally open. Default: 0.
Size: 1 byte dec
Shock Trigger Delay
Parameter 12: The amount of time the device waits to send a shock notification after the first shock event is detected.
Values: 0 – No delay; 1-10 (50-500 milliseconds). Default: 5.
Size: 1 byte dec
Disable Shock Sensor Conditionally
Parameter 13: Disable shock sensor based on the tilt sensor's open / close status. See documentation for details (expert users only).
Values: 0 – Enabled regardless of status; 1 – Disabled when tilt in open status; 2 – Disabled when tilt in closed status. Default: 0.
Size: 1 byte dec
Tilt Sensor Open Angle
Parameter 14: Set the angle of the tilt sensor open state (the status will change if the physical tilt angle exceeds the set value).
Values: 60-90 (degrees). Default: 80.
Size: 1 byte dec
Tilt Sensor Closed Angle
Parameter 15: Set the angle of the tilt sensor close state (the status will change if the physical tilt angle falls below the set value).
Values: 0-20 (degrees). Default: 5.
Size: 1 byte dec
Tilt Sensor Calibration
Parameter 16: Set the device to value 1 to enter manual calibration mode if the default position of the sensor exceeds 5 degrees. Then wake the sensor up manually (click the Z-Wave button 4 times quickly) to calibrate. After calibration is complete, revert the parameters value to 0 to exit calibration mode. Expert users only.
Values: 0 – Exit calibration mode; 1 – Enter calibration mode. Default: 0.
Size: 1 byte dec
Tilt Sensor Direction
Parameter 17: Choose which tilt direction the sensor should report to the hub (expert users only).
Values: 0 – Vertical tilt enabled, horizontal tilt disabled; 1 – Vertical tilt enabled, horizontal tilt enabled; 2 – Vertical tilt disabled, horizontal tilt enabled. Default: 0
Size: 1 byte dec
How to Access the Advanced Settings
How to Access the Advanced Settings for the ZSE43 on Home Assistant
How to Access the Advanced Settings for the ZSE43 on HomeSeer
How to Access the Advanced Settings for the ZSE43 on Hubitat
How to Access the Advanced Settings for the ZSE43 on SmartThings
How to Access the Advanced Settings for the ZSE43 on Z-Box
Association Groups
Group 1: Lifeline to hub
Group 2: Basic set for open / close (tilt sensor)
Group 3: Basic set for vibration / on vibration (shock sensor)
Manual Wake-Up
Remember to click the Z-Wave button 4 times quickly to wake the sensor up after updating the settings for the changes to be pushed to the device immediately. Otherwise, the setting changes will be accepted at the next pre-set wake interval for the sensor.
Your Tilt | Shock Sensor can be updated via OTA firmware updates. You can access all firmware files here. Questions? Just reach out to our tech support team.