Here is a full list of advanced settings (parameters) for the ZEN54 0-10 V Dimmer VER. 1.10 firmware:

On / Off Status After Power Failure

Parameter 1: Set the on/off status or brightness level for the dimmer after power failure.

Values: 

0 – forced to OFF (regardless of state prior to power outage);

1-99 – forced to ON at the selected brightness level (regardless of state prior to power outage);

100 – remembers and restores on/off status or brightness level after power failure (default);

Size: 1 byte dec

LED Indicator

Parameter 2: Enable or disable the LED indicator to reflect the current on/off status of the connected load (LED on when the load is on, LED off when the load is off).

Values: 

0 – LED Indicator disabled;

1 – LED Indicator enabled (default).

Size: 1 byte dec

Dimming Speed

Parameter 3: Adjust the dimming speed (fade-in / fade-out) for your dimmer when the light is turned on and off from the switch or via Z-Wave. Values correspond to the number of seconds it take for the dimmer to reach full brightness or completely turn off.

Values: 

0 – instant on/off;

1 – 99 (seconds).

Default: 5.

Size: 2 byte dec

Minimum and Maximum Brightness

Parameter 4: Set the minimum brightness level (in %) for your dimmer. You won’t be able to dim the light below the set value.

Values: 1 – 45 (%). Default: 1.

Size: 1 byte dec

 

Parameter 5: Set the maximum brightness level (in %) for your dimmer. You won’t be able to add brightness to the light beyond the set value.

Values: 55 – 99 (%). Default: 99.

Size: 1 byte dec

 

Parameter 6: Set the kickstart brightness level (in %) for your dimmer. This setting is useful for fixtures that won't turn on when starting from a low brightness level.

Values: 

0 – Disabled (default).

1 – 99 (%).

Size: 1 byte dec

Wall Switch Control

Parameter 7: Enable or disabled Z-Wave inclusion activation from the wall switch.

Values: 

0 – Inclusion mode from switch disabled;

1 – Inclusion mode from switch enabled (default).

Size: 1 byte dec

 

Parameter 12: Choose the type of wall switch connected to the 0-10 V dimmer.

Values: 

0 – toggle switch (device changes status when switch changes status); 

1 – momentary switch (one-button switch like the ZAC99);

2 – toggle switch with fixed actions (always toggle up for on, always toggle down for off); 

3 – 3-way impulse control (for selected 3-way scenarios, refer to the notes in the wiring instructions for your set-up).

Default: 2.

Size: 1 byte dec

Auto Turn-Off Timer

Parameter 8: Use this parameter to set the time after which you want the light connected to the dimmer to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes or seconds (set the unit in Par. 10).
Values: 

0 – timer disabled (default);

1 – 4294967295.
Size: 4 byte dec.

Auto Turn-On Timer

Parameter 9: Use this parameter to set the time after which you want the light connected to the dimmer to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes or seconds (set the unit in Par. 10).
Values: 

0 – timer disabled (default);

1 – 4294967295.
Size: 4 byte dec.

Timer Unit

Parameter 10: Choose between seconds and minutes as the unit for the timers in parameters 8 and 9.

Values: 1 – minutes (default); 2 – seconds.

Size: 1 byte dec

Smart Bulb Mode: Enable/Disable Switch / Z-Wave Control

Parameter 11: Enable or disable physical and/or Z-Wave on/off control. If disabled, you’ll only be able to control the connected light via Z-Wave.

Values: 

0 – button and wall switch control disabled, Z-Wave control enabled (the dimmer will still report on/off control to the hub whenever the button or switch are toggled); 

1 – button, wall switch, and Z-Wave control enabled (default); 

2 – button, wall switch, and Z-Wave control control disabled (the dimmer will still report on/off control to the hub whenever the button or switch are toggled physically or via Z-Wave).

Size: 1 byte dec

Association Reports

Parameter 13: Choose the type of reports the relay will send to the hub for Z-Wave and external switch control.

Values: 

0 – switch multilevel reports for Z-Wave control and basic reports for switch control; 

1 – switch multilevel reports for both Z-Wave and switch control (default).

Size: 1 byte dec

Dimmer Off Behavior

Parameter 14: Choose if you'd like the dimmer to cut power off completely to the 0-10 V driver when in the off position to prevent a glowing effect on the light (applicable to selected 0-10 V fixtures).

Values: 

0 – Keep the power on to the LED driver when the 0-10 V Dimmer is off; 

1 – Cut the power off to the LED driver when the 0-10 V Dimmer is off (default).

Size: 1 byte dec

Ramp Rate Control

Parameter 15: Physical Ramp Rate On. Adjust the ramp rate ON for your dimmer when the button paddle is pressed (physical ramp rate on). The Values correspond to the number of seconds required to switch on the dimmer when operated manually.
Values:

0 – instant ON

1- 99 seconds  (default: 5)
Size: 1 byte dec

 

Parameter 16: Physical Ramp Rate Off. Adjust the ramp rate OFF for your dimmer when the button paddle is pressed (physical ramp rate off). The Values correspond to the number of seconds required to switch off the dimmer when operated manually.
Values:

0 – instant OFF

1- 99 seconds (default: 5)
Size: 1 byte dec

 

Parameter 17: Z-Wave Ramp Rate On. Adjust the ramp rate ON for your dimmer when a Z-Wave command is sent to turn the dimmer on (Z-Wave ramp rate on). The Values correspond to the number of seconds it take for the dimmer to reach full brightness when operated via Z-Wave.
Values:

0 – instant ON
1- 99 seconds
100 – match parameter 15 value (default)
Size: 1 byte dec

 

Parameter 18: Z-Wave Ramp Rate Off. Adjust the ramp rate OFF for your dimmer when a Z-Wave command is sent to turn the dimmer off (Z-Wave ramp rate off). The Values correspond to the number of seconds it take for the dimmer to turn off when operated via Z-Wave.
Values:

0 – instant OFF
1- 99 seconds
100 – match parameter 16 value (default)
Size: 1 byte dec

MANUAL CONTROL FROM THE Z-WAVE BUTTON

3 x tap: enter inclusion (pairing) or exclusion mode

2 x tap and hold (the third time) for 15 seconds: factory reset

 

Supported Command Classes:

COMMAND_CLASS_ZWAVEPLUS_INFO_V2 
COMMAND_CLASS_TRANSPORT_SERVICE_V2 
COMMAND_CLASS_SECURITY_2_V1 
COMMAND_CLASS_SUPERVISION_V1 
COMMAND_CLASS_APPLICATION_STATUS_V1 
COMMAND_CLASS_BASIC_V2 
COMMAND_CLASS_SWITCH_MULTILEVEL _V4 
COMMAND_CLASS_CONFIGURATION_V4 
COMMAND_CLASS_ASSOCIATION_V2 
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 
COMMAND_CLASS_VERSION_V3 
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 
COMMAND_CLASS_POWERLEVEL_V1 
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 
COMMAND_CLASS_INDICATOR_V3 

 

The ZEN54 0-10 V Dimmer can be updated via OTA firmware updates, here is how to do that. You can access all firmware files here once you register your product and create an account here. Questions? Just reach out to our support!

Feedback
0 out of 0 found this helpful

Have you tried our virtual assistant chatbot? This AI tool can help you find answers from thousands of articles in our Knowledge Base quickly. Find it in the bottom righthand corner of the page.

Need more help? Our friendly team is ready to help you with any questions or concerns you may have about Zooz devices. Click here to submit a support ticket.

Are your devices registered? Extended warranty and firmware access is available for registered Zooz customers. Click here to submit your registration form.

Find the latest Zooz devices and great Z-Wave deals at The Smartest House.
 
scroll to top icon