So you've got your ZEN54 installed? Great! Let's get it included to your Z-Wave hub. Simply follow the steps below to have the ZEN54 included in no time!
Important Note: A steady, blinking green is the standard state for the device; as long as the unit has power, it will blink green at a steady pace. The device has an internal relay, which can turn on and off with a click of the Z-Wave button. This means that when you are attempting to include or exclude the device, the clicks need to happen as fast as possible; if the clicks are not completed fast enough, the relay will engage instead and the device will not enter inclusion or exclusion mode. You will know you have clicked fast enough when the LED indicator begins flashing rapidly.
To auto-include your ZEN54 0-10V Dimmer:
- Put your Z-Wave hub into inclusion/pairing mode (see your hub's manual for instructions since each brand is different). If you’re using an S2 hub, it may ask you to enter the DSK key printed on the back cover sticker to complete secure inclusion
- The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful.
To manually include your ZEN54 0-10V Dimmer:
- Put the Z-Wave hub into inclusion/pairing mode (see your hub's manual for instructions since each brand is different)
- Click the Z-Wave button 3 times quickly.
- The LED indicator will blink green to signal communication and turn green for 2 seconds if inclusion is successful.
- The new device should appear on your hub's device list
If you've tried auto and manual inclusion but you're still unable to include the ZEN54 0-10V Dimmer, please try to exclude the device, then try inclusion again.