Here is a full list of advanced settings (parameters) for the ZSE70 Outdoor Motion Sensor:

 

Parameter 1: Motion Sensitivity

Set motion sensitivity for the motion detector to minimize false alerts.

Values: 0 – disable motion reports; 1 – 8 where 8 is the most sensitive and 1 is the least sensitive.

Default: 6

Size: 1 byte dec

 

Parameter 2: Motion Clear Delay

The amount of time the device waits to send a motion clear notification after the last motion event is detected.

Values: 10-3600 seconds

Default: 30

Size: 2 bytes dec

 

Parameter 3: Basic Set Reporting

Basic set values sent by the sensor for motion / no-motion events sent to associated devices.

Values:

0 - Disable Basic Set Reports
1 - Basic Set 0xFF For Motion / Basic Set 0x00 For No Motion
2 - Basic Set 0x00 For Motion / Basic Set 0xFF For No Motion
3 - Basic Set 0xFF For Motion / No Reports For No Motion
4 - Basic Set 0x00 For Motion / No Reports For No Motion
5 - No Reports For Motion / Basic Set 0x00 For No Motion
6 - No Reports For Motion / Basic Set 0xFF For No Motion 
7 - Custom Report For Motion / Custom Report For No Motion (set in par 4)

Default: 7

Size: 1 byte dec

 

Parameter 4: Custom Basic Set Reports

High byte is the value sent when motion is detected, low byte is the value sent when motion is cleared. 

e.g:0x0A00 means:
 When motion is detected, Send Basic Set(0A),
 When motion is cleared, send Basic Set(00)

Values: Configurable values.

Default: 65280

Size: 2 bytes dec

 

Parameter 5: Temperature Report Unit

Set the temperature report unit.

Values: 0 - Celsius; 1 - Fahrenheit.

Default: 1

Size: 1 byte dec

 

Parameter 6: LED For Motion

Decide whether you want the LED indicator to light up when motion is detected or not.

Values: 0 – LED Off; 1 – LED On.

Default: 1

Size: 1 bytes dec

 

Parameter 7: Low Battery Alert

Set the low battery threshold to receive an alert when battery is running low.

Values: 10-50 %

Default: 10

Size: 1 byte dec

 

Parameter 8: Battery Check Frequency

Set how often you want the device to check battery power for changes (this is not a reporting frequency setting).

Values: 0 - Disable (the device won't check for battery power changes and won't send reports to the hub); 1 - 744 hours.

Default: 4

Size: 1 byte dec

 

Parameter 9: Temperature Check Frequency​​​​​​​

Set how often you want the device to check ambient temperature for changes (this is not a reporting frequency setting).

Values: 0 - Disable (the device won't check for temperature changes and won't send temperature reports to the hub); 1 - 600 seconds.

Default: 20

Size: 2 byte dec

 

Parameter 10: Lux Check Frequency​​​​​​​

Set how often you want the device to check lux level for changes (this is not a reporting frequency setting).

Values: 0 - Disable (the device won't check for lux changes and won't send lux reports to the hub); 1 - 600 seconds.

Default: 10

Size: 2 byte dec

 

Parameter 11: Battery Reporting Threshold

Set when you want the device to send battery reports. This setting specifies the amount of % change the battery needs to record in order for the device to send a new battery report to the hub.

Values: 0 - Ignore (the device won't send battery reports to the hub); 1 - 50 %.

Default: 2

Size: 1 byte dec

 

Parameter 12: Temperature Reporting Threshold

Set when you want the device to send temperature reports. This setting specifies the amount of F degree change the sensor needs to record in order for the device to send a new temperature report to the hub.

Values: 0 - Ignore (the device won't send temperature reports to the hub); 1 - 144.

Default: 1

Size: 1 byte dec

 

Parameter 13: Lux Reporting Threshold

Set when you want the device to send lux level reports. This setting specifies the amount of lux change the sensor needs to record in order for the device to send a new lux level report to the hub.

Values: 0 - Ignore (the device won't send lux reports to the hub); 1 - 30000.

Default: 50

Size: 2 byte dec

 

Parameter 14: Temperature Offset

Set the temperature reporting offset. Value 100 is zero offset; values 0-99 decrease the value (ex: 56 means deduct 4.4 degrees from the measured value); values 101-200 increase the value (ex: value 121 means add 2.1 degree to the reported value). NOTE: Device must be factory reset to restore this value to default.

Values: 0 – 200. 

Default: 100 (no offset). 

Size: 1 byte dec

 

Parameter 15: Lux Offset

Set the lux reporting offset. Value 100 is zero offset; values 0-99 decrease the value (ex: 75 means deduct 25 lux from the measured value); values 101-200 increase the value (ex: value 147 means add 47 lux to the measured value). NOTE: Device must be factory reset to restore this value to default.

Values: 0 – 200. 

Default: 100 (no offset). 

Size: 1 byte dec

 

Parameter 16: Lux Level Trigger

Set the lux level trigger. If brightness level is lower than the set lux value, the sensor will send a motion event notification to the hub.

Values: 0 –  Ignore (motion always reported when detected); 1 - 30000 lux (motion reports will only be sent if lux level is lower than the set value).

Default: 0.

Size: 2 byte dec

 

Parameter 17: Temperature Reporting Frequency

Set the reporting interval for temperature. Values 1-43200 will send a report regardless of the threshold value selected in parameter 12.

Values: 0 – Ignore, reports based on threshold only (value set in parameter 12). 1 - 43200 seconds.

Default: 0.

Size: 2 byte dec

 

Parameter 18: Lux Reporting Frequency

Set the reporting interval for lux level. Values 1-43200 will send a report regardless of the threshold value selected in parameter 13.

Values: 0 – Ignore, reports based on threshold only (value set in parameter 13). 1 - 43200 seconds.

Default: 0.

Size: 2 byte dec

 

The Outdoor Motion Sensor can be updated via OTA firmware updates, here is how to do that. You can access all firmware files here. Remember to register your product and create an account here for extended warranty and priority troubleshooting. Questions? Just reach out to our support!

Feedback
0 out of 0 found this helpful

Have you tried our virtual assistant chatbot? This AI tool can help you find answers from thousands of articles in our Knowledge Base quickly. Find it in the bottom righthand corner of the page.

Need more help? Our friendly team is ready to help you with any questions or concerns you may have about Zooz devices. Click here to submit a support ticket.

Are your devices registered? Extended warranty and firmware access is available for registered Zooz customers. Click here to submit your registration form.

Find the latest Zooz devices and great Z-Wave deals at The Smartest House.
 
scroll to top icon