Here is a full list of advanced settings (parameters) for the ZSE70 Outdoor Motion Sensor:
Parameter 1: Motion Sensitivity
Set motion sensitivity for the motion detector to minimize false alerts.
Values: 0 – disable motion reports; 1 – 8 where 8 is the most sensitive and 1 is the least sensitive.
Default: 6
Size: 1 byte dec
Parameter 2: Motion Clear Delay
The amount of time the device waits to send a motion clear notification after the last motion event is detected.
Values: 10-3600 seconds
Default: 30
Size: 2 bytes dec
Parameter 3: Basic Set Reporting
Basic set values sent by the sensor for motion / no-motion events sent to associated devices.
Values:
0 - Disable Basic Set Reports
1 - Basic Set 0xFF For Motion / Basic Set 0x00 For No Motion
2 - Basic Set 0x00 For Motion / Basic Set 0xFF For No Motion
3 - Basic Set 0xFF For Motion / No Reports For No Motion
4 - Basic Set 0x00 For Motion / No Reports For No Motion
5 - No Reports For Motion / Basic Set 0x00 For No Motion
6 - No Reports For Motion / Basic Set 0xFF For No Motion
7 - Custom Report For Motion / Custom Report For No Motion (set in par 4)
Default: 7
Size: 1 byte dec
Parameter 4: Custom Basic Set Reports
High byte is the value sent when motion is detected, low byte is the value sent when motion is cleared.
e.g:0x0A00 means:
When motion is detected, Send Basic Set(0A),
When motion is cleared, send Basic Set(00)
Values: Configurable values.
Default: 65280
Size: 2 bytes dec
Parameter 5: Temperature Report Unit
Set the temperature report unit.
Values: 0 - Celsius; 1 - Fahrenheit.
Default: 1
Size: 1 byte dec
Parameter 6: LED For Motion
Decide whether you want the LED indicator to light up when motion is detected or not.
Values: 0 – LED Off; 1 – LED On.
Default: 1
Size: 1 bytes dec
Parameter 7: Low Battery Alert
Set the low battery threshold to receive an alert when battery is running low.
Values: 10-50 %
Default: 10
Size: 1 byte dec
Parameter 8: Battery Check Frequency
Set how often you want the device to check battery power for changes (this is not a reporting frequency setting).
Values: 0 - Disable (the device won't check for battery power changes and won't send reports to the hub); 1 - 744 hours.
Default: 4
Size: 1 byte dec
Parameter 9: Temperature Check Frequency
Set how often you want the device to check ambient temperature for changes (this is not a reporting frequency setting).
Values: 0 - Disable (the device won't check for temperature changes and won't send temperature reports to the hub); 1 - 600 seconds.
Default: 20
Size: 2 byte dec
Parameter 10: Lux Check Frequency
Set how often you want the device to check lux level for changes (this is not a reporting frequency setting).
Values: 0 - Disable (the device won't check for lux changes and won't send lux reports to the hub); 1 - 600 seconds.
Default: 10
Size: 2 byte dec
Parameter 11: Battery Reporting Threshold
Set when you want the device to send battery reports. This setting specifies the amount of % change the battery needs to record in order for the device to send a new battery report to the hub.
Values: 0 - Ignore (the device won't send battery reports to the hub); 1 - 50 %.
Default: 2
Size: 1 byte dec
Parameter 12: Temperature Reporting Threshold
Set when you want the device to send temperature reports. This setting specifies the amount of F degree change the sensor needs to record in order for the device to send a new temperature report to the hub.
Values: 0 - Ignore (the device won't send temperature reports to the hub); 1 - 144.
Default: 1
Size: 1 byte dec
Parameter 13: Lux Reporting Threshold
Set when you want the device to send lux level reports. This setting specifies the amount of lux change the sensor needs to record in order for the device to send a new lux level report to the hub.
Values: 0 - Ignore (the device won't send lux reports to the hub); 1 - 30000.
Default: 50
Size: 2 byte dec
Parameter 14: Temperature Offset
Set the temperature reporting offset. Value 100 is zero offset; values 0-99 decrease the value (ex: 56 means deduct 4.4 degrees from the measured value); values 101-200 increase the value (ex: value 121 means add 2.1 degree to the reported value). NOTE: Device must be factory reset to restore this value to default.
Values: 0 – 200.
Default: 100 (no offset).
Size: 1 byte dec
Parameter 15: Lux Offset
Set the lux reporting offset. Value 100 is zero offset; values 0-99 decrease the value (ex: 75 means deduct 25 lux from the measured value); values 101-200 increase the value (ex: value 147 means add 47 lux to the measured value). NOTE: Device must be factory reset to restore this value to default.
Values: 0 – 200.
Default: 100 (no offset).
Size: 1 byte dec
Parameter 16: Lux Level Trigger
Set the lux level trigger. If brightness level is lower than the set lux value, the sensor will send a motion event notification to the hub.
Values: 0 – Ignore (motion always reported when detected); 1 - 30000 lux (motion reports will only be sent if lux level is lower than the set value).
Default: 0.
Size: 2 byte dec
Parameter 17: Temperature Reporting Frequency
Set the reporting interval for temperature. Values 1-43200 will send a report regardless of the threshold value selected in parameter 12.
Values: 0 – Ignore, reports based on threshold only (value set in parameter 12). 1 - 43200 seconds.
Default: 0.
Size: 2 byte dec
Parameter 18: Lux Reporting Frequency
Set the reporting interval for lux level. Values 1-43200 will send a report regardless of the threshold value selected in parameter 13.
Values: 0 – Ignore, reports based on threshold only (value set in parameter 13). 1 - 43200 seconds.
Default: 0.
Size: 2 byte dec
The Outdoor Motion Sensor can be updated via OTA firmware updates, here is how to do that. You can access all firmware files here. Remember to register your product and create an account here for extended warranty and priority troubleshooting. Questions? Just reach out to our support!