The ZEN72 700 series Dimmer has a lot of cool advanced features, like enabling scene control and setting up smart bulb mode.
Below are instructions for changing any parameter for your ZEN72 in your Vera interface; we used on/off status recovery as an example, but the same steps apply for any other parameter. The complete list of parameter details can be found here. Unfortunately, Vera doesn't currently support the scene control (multi-tap) functionality of our switches.
How to change an advanced setting parameter for your ZEN72 in Vera:
- Open your Vera online interface (the browser dashboard, not the app)
- Click on the Zooz ZEN72 Dimmer Switch
- Go to Device Options
- Click on Add configuration settings
- Put in the following to change on/off status after power failure:
- Variable = 8
- Data Size = 1 byte dec
- Desired Value = [0 – forced to OFF (regardless of state prior to power outage); 1 – forced to ON (regardless of state prior to power outage); 2 – remembers and restores on/off status after power failure (default)]
- Click on Save Changes
If you have any questions about the ZEN72 or another Zooz device, let our team know!