Here is a full list of advanced settings (parameters) for the ZEN32 Scene Controller:
Some parameters were added in later firmware updates so please make sure you're on the latest firmware to have all of the settings below available. You can view the change log for the ZEN32 here.
LED indicator mode for relay button
Parameter 1: Choose if you want the LED indicator to turn on when the relay is on or off, or if you want it to remain on or off at all times.
Values: 0 – LED on when relay off, LED off when relay on (default) ; 1 – LED on when relay on, LED off when relay off; 2 – LED always off; 3 – LED always on
Size: 1 byte dec
LED indicator mode for button 1
Parameter 2: Choose if you want the LED indicator to turn on when Button 1 is on or off, or if you want it to remain on or off at all times.
Values: 0 – LED on when button off, LED off when button on (default); 1 – LED on when button on, LED off when button off; 2 – LED always off; 3 – LED always on
Size: 1 byte dec
LED indicator mode for button 2
Parameter 3: Choose if you want the LED indicator to turn on when Button 2 is on or off, or if you want it to remain on or off at all times.
Values: 0 – LED on when button off, LED off when button on (default); 1 – LED on when button on, LED off when button off; 2 – LED always off; 3 – LED always on
Size: 1 byte dec
LED indicator mode for button 3
Parameter 4: Choose if you want the LED indicator to turn on when Button 3 is on or off, or if you want it to remain on or off at all times.
Values: 0 – LED on when button off, LED off when button on (default); 1 – LED on when button on, LED off when button off; 2 – LED always off; 3 – LED always on
Size: 1 byte dec
LED indicator mode for button 4
Parameter 5: Choose if you want the LED indicator to turn on when Button 4 is on or off, or if you want it to remain on or off at all times.
Values: 0 – LED on when button off, LED off when button on (default); 1 – LED on when button on, LED off when button off; 2 – LED always off; 3 – LED always on
Size: 1 byte dec
LED indicator color for the relay button
Parameter 6: Choose the color of the LED indicator for the relay.
Values: 0 – white (default); 1 – blue; 2 – green; 3 – red; 4 – magenta (RB); 5 – yellow (RG); 6 – cyan (GB)
Size: 1 byte dec
LED indicator color for button 1
Parameter 7: Choose the color of the LED indicator for Button 1.
Values: 0 – white (default); 1 – blue; 2 – green; 3 – red; 4 – magenta (RB); 5 – yellow (RG); 6 – cyan (GB)
Size: 1 byte dec
LED indicator color for button 2
Parameter 8: Choose the color of the LED indicator for Button 2.
Values: 0 – white (default); 1 – blue; 2 – green; 3 – red; 4 – magenta (RB); 5 – yellow (RG); 6 – cyan (GB)
Size: 1 byte dec
LED indicator color for button 3
Parameter 9: Choose the color of the LED indicator for Button 3.
Values: 0 – white (default); 1 – blue; 2 – green; 3 – red; 4 – magenta (RB); 5 – yellow (RG); 6 – cyan (GB)
Size: 1 byte dec
LED indicator color for button 4
Parameter 10: Choose the color of the LED indicator for Button 4.
Values: 0 – white (default); 1 – blue; 2 – green; 3 – red; 4 – magenta (RB); 5 – yellow (RG); 6 – cyan (GB)
Size: 1 byte dec
LED indicator brightness for the relay button
Parameter 11: Choose the LED indicator's brightness level for the relay.
Values: 0 – bright (100%); 1 – medium (60%) (default); 2 – low (30%)
Size: 1 byte dec
LED indicator brightness for button 1
Parameter 12: Choose the LED indicator's brightness level for Button 1.
Values: 0 – bright (100%); 1 – medium (60%) (default); 2 – low (30%)
Size: 1 byte dec
LED indicator brightness for button 2
Parameter 13: Choose the LED indicator's brightness level for Button 2.
Values: 0 – bright (100%); 1 – medium (60%) (default); 2 – low (30%)
Size: 1 byte dec
LED indicator brightness for button 3
Parameter 14: Choose the LED indicator's brightness level for Button 3.
Values: 0 – bright (100%); 1 – medium (60%) (default); 2 – low (30%)
Size: 1 byte dec
LED indicator brightness for button 4
Parameter 15: Choose the LED indicator's brightness level for Button 4.
Values: 0 – bright (100%); 1 – medium (60%) (default); 2 – low (30%)
Size: 1 byte dec
Enable/disable LED indicator for settings
Parameter 23: Choose if you want the LED indicators to flash whenever a parameter (setting) is adjusted on the device to confirm the change. Disable this feature if you're using the LED indicators in automation.
Values: 0 – LED indicators flash to confirm a setting change (default); 1 – LED indicators don't flash if a setting is changed.
Size: 1 byte dec
Enable/disable LED blinking when buttons are pressed
Parameter 27: Choose if you want the LED indicators to flash whenever a button is pressed on the device to confirm scene activation.
Values: 0 - LED blinking enabled; 1 - LED blinking disabled. Default: 0
Size: 1 byte dec
Auto turn-off timer for relay
Parameter 16: Use this parameter to enable or disable the auto turn-off timer function (the time after which you want the switch to automatically turn off once it has been turned on).
Values: 0 – disabled (default); 1 – 65535 (minutes)
Size: 4 byte dec
Auto turn-on timer for relay
Parameter 17: Use this parameter to enable or disable the auto turn-on timer function (the time after which you want the switch to automatically turn on once it has been turned off).
Values: 0 – disabled (default); 1 – 65535 (minutes)
Size: 4 byte dec
State after power failure
Parameter 18: Set the on off status for the switch after power failure.
Values: 0 – Relay and buttons remember and restore last state (default); 1 – Relay and buttons forced to off after power failure; 2 – Relay and buttons forced to on after power failure
Size: 1 byte dec
Disable / enable control on the relay
Parameter 19: Enable or disable paddle on/off control (aka disable the relay). If disabled, you’ll only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through buttons.
Values: 0 – Disable local/physical control (from the button), enable Z-Wave control; 1 – Enable local/physical control (from the button), enable Z-Wave control (default); 2 – Disable local/physical control (from the button), disable Z-Wave control
Size: 1 byte dec
Relay behavior with disabled local / Z-Wave control
Parameter 20: Set reporting behavior for disabled physical control.
Values: 0 – report on/off status when the button is pressed and change LED indicator status if Parameter 19 is set to value 0 or 2; 1 – DON’T report on/off status when the button is pressed and DON’T change LED indicator status if Parameter 19 is set to value 0 or 2 (but the relay will always send central scene command) (default)
Size: 1 byte dec
3-way switch type
Parameter 21: Choose the type of 3-way switch you want to use with this switch in a 3-way set-up.
Values: 0 – regular mechanical 3-way on/off switch, use the connected 3-way switch to turn the light on or off (default); 1 – momentary switch, click once to change status (light on or off)
Size: 1 byte dec
Association Reports
Parameter 25: Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to the associated devices in Group 2.
Values: 0 – none; 1 – physical tap on ZEN32 only; 2 - physical tap on connected 3-way switch only; 3 - physical tap on ZEN32 or connected 3-way switch; 4 - Z-Wave command from hub; 5 - physical tap on ZEN32 or Z-Wave command from hub; 6 - physical tap on connected 3-way switch or Z-Wave command from hub; 7 - physical tap on ZEN32 / connected 3-way switch or Z-Wave command from hub; 8 - timer only; 9 - physical tap on ZEN32 or timer; 10 - physical tap on connected 3-way switch or timer; 11 - physical tap on ZEN32 / connected 3-way switch or timer; 12 - Z-Wave command from hub or timer; 13 - physical tap on ZEN32, Z-Wave command from hub, or timer; 14 - physical tap on ZEN32 / connected 3-way switch, Z-Wave command from hub, or timer; 15 - all of the above. Default: 15.
Size: 1 byte dec
Enable/disable programming on the relay button
Parameter 22: Enable or disable programming functionality on the relay button. If this setting is disabled, then inclusion, exclusion, manual LED indicator change mode no longer work when the relay button is activated (factory reset and scene control will still work) - that means you can now use triple-tap triggers on the relay button for scenes and remote control of other devices.
Values: 0 – programming enabled (default). 1 – programming disabled.
Size: 1 byte dec
Enable/disable scene control on the relay button
Parameter 24: Enable or disable scene control on the relay button. If scene control is disabled, the slight delay for physical press will be reduced but the relay button will no longer send central scene events to the hub. It's recommended to disable the feature only if using the relay button for direct electrical control of the connected load without any additional remote-control functions.
Values: 0 – scene control enabled (default). 1 – Scene control disabled.
Size: 1 byte dec
Parameter 26: Enable scene control functionality from the momentary switch in a 3-way installation.
Values: 0 – scene control disabled commands from the remote 3-way switch disabled (default). 1 – Scene control commands from the remote 3-way switch enabled. Default: 0
Size: 1 byte dec
MANUAL CONTROL:
Inclusion/Exclusion: 3x tap on the main button. The LED indicator flashes green while processing. Successful: solid green LED for 3 seconds. Failed: Solid red for 3 seconds
Factory Reset: Press and hold the main button for 20 seconds until the LED indicator turns solid red; within 2 seconds click button 1 to confirm the reset. All LED indicators on all buttons will flash red for 3 seconds to indicate a successful reset.
LED Indicator Mode: Tap 1x then press & hold the main button for 5 seconds, until the LED indicator turns solid green. Then click the button that you want to change the setting 3 times quickly to rotate the values in Parameters 1-5. (So relay button 3 times click to rotate values for Par 1, Button #1 3 times click to rotate values for Par 2, etc.) The LED indicator will flash green 2 times to indicate a mode change.
Disable/Enable Relay Control: Tap the main button 1x then press and hold it for 5 seconds until the LED indicator turns solid green. Then click the relay button 5 times quickly to rotate values in Parameter 19. The LED indicator will flash green 2 times to indicate a successful mode change.
Range Test Tool: press and hold the main button for 20 seconds, until the LED indicator turns solid red. Within 2 seconds, click button 4 to enter range test mode. All LED indicators will start blinking white while testing. All LED indicators will then report signal strength:
Solid Green = direct communication with the primary controller is stable
Flashing Green = direct communication with the primary controller is established, but signal is weak
Solid Blue = stable communication with hub via repeaters
Flashing Blue = communication with the primary controller is established via repeaters but signal is weak
Solid Red = communication with the primary controller has failed
ASSOCIATIONS:
Group 1: Main button binary switch (Z-Wave) / basic set (button) lifeline to hub
Group 2: Main button basic set (pressed only, doesn’t send anything when switch turned on via hub)
Group 3: Main button multilevel (held)
Group 4: Small button #1 basic set (pressed)
Group 5: Small button #1 multilevel (held) > in sequence > held = increase brightness, release = stop level, held = decrease brightness, release = stop level
Group 6: Small button #2 basic set (pressed)
Group 7: Small button #2 multilevel (held) > in sequence > held = increase brightness, release = stop level, held = decrease brightness, release = stop level
Group 8: Small button #3 basic set (pressed)
Group 9: Small button #3 multilevel (held) > in sequence > held = increase brightness, release = stop level, held = decrease brightness, release = stop level
Group 10: Small button #4 basic set (pressed)
Group 11: Small button #4 multilevel (held) > in sequence > held = increase brightness, release = stop level, held = decrease brightness, release = stop level
SUPPORTED COMMAND CLASSES:
Z-Wave Plus Info V2
Security 2 V1
Supervision V1
Transport Service V2
Basic V2
Association V2
Association Group Information V3
Multi Channel Association V3
Version V3
Manufacturer Specific V2
Device Reset Locally V1
Power Level V1
Indicator V3
Firmware Update Meta Data V5
Configuration V4
Central Scene V3
Switch Binary V2
How to Access the Advanced Settings:
The ZEN32 Scene Controller can be updated via OTA firmware updates, here is how to do that. You can access all firmware files here after you register your product and create an account here. Questions? Just reach out to our tech support team.