Wondering if your Titan Water Valve Actuator is behaving correctly? Here is a list of the LED indicator sequences and beep sounds you should see when performing all of the device's basic functions.

The Titan will fit on valves up to 1.25". Is your pipe larger? Reach out to us about an extension kit for the ZAC36 to accommodate larger pipes/valves.

 

Power on:

  • Yellow flash
  • Green solid on with continuous beep for 2 seconds

Standby when powered on:

  • When not included to a Z-Wave hub: yellow blink (at around 1 Hz frequency so every half second)
  • When included to a Z-Wave hub: green pulse (every 2 seconds)

Z-Wave button clicked:

  • Green flash and 1 beep (anytime you successfully tapped the button)

Operation completed successfully:

  • Flashing green and 2 beeps

Operation failed:

  • Slow flashing red and 3 beeps

Operation incomplete (timeout):

  • Fast flashing red and 3 beeps

Valve opening:

  • Click the Z-Wave button once (flashes green and beeps once) to initiate
  • Fast flashing green and fast beeping when opening
  • Green flash and 2 beeps to indicate success (valve open)
  • Slow flashing red and 3 beeps to indicate failure (valve not fully open)

Valve closing:

  • Click the Z-Wave button once (flashes green and beeps once) to initiate
  • Fast flashing yellow and fast beeping when closing
  • Green flash and 2 beeps to indicate success (valve closed)
  • Slow flashing red and 3 beeps to indicate failure (valve not fully closed)

Pause opening or closing:

  • Only available after manual calibration
  • Click the Z-Wave button once (flashes green and beeps once) to pause when the actuator is in the process of opening or closing the valve
  • 2 green flashes and NO beep to indicate success (operation paused), the valve stops moving
  • Yellow flashing (every half second) when the operation is paused

Resume opening or closing:

  • Only available if the operation has been previously paused
  • Click the Z-Wave button once (flashes green and beeps once) to resume opening or closing when the processed is paused
  • Actuator will go back to the starting position (it will start moving in reverse direction than before it was paused)
  • When complete, the actuator will go back to standby mode (yellow flashing when not included to Z-Wave hub or pulsing green when included to Z-Wave hub)

Initial calibration:

  • Perform after installing the Titan actuator on your water valve
  • Hold the Z-Wave button until 2 beeps sound to initiate
  • Quick flashing yellow during the calibration process (the actuator will open and close to find the start and end points)
  • Flashing green and 2 beeps to indicate successful calibration

Initial calibration failed:

  • Slow flashing red and 3 beeps to indicate failed calibration
  • Green and red flashing in incomplete calibration mode
  • To exit the failed calibration mode, hold the Z-Wave button until 2 beeps sound
  • Actuator will go back to the starting position and standby mode (yellow flashing when not included to Z-Wave hub or pulsing green when included to Z-Wave hub)

Forced calibration:

  • Perform when the initial calibration fails or when moving the Titan from one installation to another
  • Hold the Z-Wave button until 5 beeps sound
  • Click the Z-Wave button 5 times to initiate forced calibration
  • Quick flashing yellow during the calibration process (the actuator will open and close to find the start and end points)
  • Flashing green and 2 beeps to indicate successful calibration

Reverse open / close commands and reports:

  • Use this method if your hub displays the open/close commands in reverse to the actual operation and doesn't give you access to change the advanced settings in the interface (if you have access to advanced settings, follow the guidelines for parameter 17 instead)
  • Hold the Z-Wave button until 4 beeps sound, release the button, then immediately after, tap the button 3 times (it will flash green and beep once each time you touch it)
  • Flashing green and 2 beeps to indicate successful setting change
  • Back to standby mode (yellow flashing when not included to Z-Wave hub or pulsing green when included to Z-Wave hub)

Z-Wave button lock enabled:

  • Lock the Z-Wave button if using the Titan Valve Actuator outdoors to prevent water damage. Once locked, you won't be able to use the Z-Wave button for anything else than to unlock it.
  • Hold the Z-Wave button until 3 beeps sound, release the button, then immediately after, tap the button 3 times (it will flash green and beep once each time you touch it)
  • Green, yellow, and red flash to indicate processing
  • 1 beep to indicate success
  • Z-Wave button lock mode indicated with slow pulsing yellow

Z-Wave button lock disabled:

  • Unlock the Z-Wave button to re-calibrate or program your device
  • Hold the Z-Wave button until 3 beeps sound, release the button, then immediately after, tap the button 3 times (it will flash green and beep once each time you touch it)
  • Green, yellow, and red flash to indicate processing
  • 3 beeps and and red slow flashing to indicate success
  • Back to standby mode (yellow flashing when not included to Z-Wave hub or pulsing green when included to Z-Wave hub)

Water leak alarm mode:

  • When a leak alarm is triggered, whether through the water probe connected directly to the Titan or through a wireless leak sensor programmed to trigger the actuator via Z-Wave, the Titan will start flashing red and beeping (every second)

Cancel the water leak alarm manually:

  • When water presence is no longer detected on the connected sensor or any of the wireless sensors in the network, you can manually cancel the leak alarm mode
  • Hold the Z-Wave button until 2 beeps sound to cancel the alarm
  • 3 green flashes and beeps to indicate success
  • Back to standby mode (yellow flashing when not included to Z-Wave hub or pulsing green when included to Z-Wave hub)

Water leak alarm automatic cancellation:

  • Only available if the Titan actuator is included to your Z-Wave hub. When water presence is no longer detected for at least 10 seconds, the alarm mode will be cancelled automatically.
  • Actuator will go from flashing and beeping red back to standby mode (pulsing green) by itself 10 seconds after the leak alarm has cleared on all of the sensors in the network

Pause water leak alarm:

  • Tap the Z-Wave button twice quickly (it will flash green and beep once each time you touch it)
  • Quick flashing yellow when the alarm is paused

Resume water leak alarm:

  • Tap the Z-Wave button once (it will flash green and beep once when you touch it) to resume the alarm after it's been paused
  • Back to water leak alarm mode: flashing red and beeping (every half second)

Z-Wave inclusion (pairing):

  • Put your Z-Wave hub in inclusion mode first
  • Tap the Z-Wave button 3 times to initiate inclusion on the device (it will flash green and beep once when you touch it)
  • Rapid yellow flashing and beeping to indicate inclusion mode
  • 2 green flashes and beeps to indicate success
  • Standby mode after successful inclusion: pulsing green
  • 3 red flashes and beeps to indicate failed inclusion or inclusion timeout

Z-Wave exclusion (removing device from the hub):

  • Put your Z-Wave hub in exclusion mode first
  • Tap the Z-Wave button 3 times to initiate exclusion on the device (it will flash green and beep once when you touch it)
  • Rapid yellow flashing and beeping to indicate inclusion mode
  • 2 green flashes and beeps to indicate success
  • Standby mode after successful exclusion: flashing yellow
  • 3 red flashes and beeps to indicate failed exclusion or exclusion timeout

Cancel the inclusion / exclusion mode:

  • Perform to exit inclusion or exclusion mode if triggered by accident
  • Tap the Z-Wave button 3 times to initiate exclusion on the device (it will flash green and beep once when you touch it)
  • 3 slow red flashes and beeps to indicate success

Factory reset:

  • Hold the Z-Wave button until 10 beeps sound, release the button, then immediately after, tap the button 5 times quickly (it will flash green and beep once when you touch it)
  • The LED indicator will turn off for 2-5 seconds
  • Yellow flash to indicate device reset
  • 2 green flashes and beeps to indicate success
  • Standby mode: flashing yellow (the device is no longer included to your Z-Wave hub)

OTA (over the air) firmware update:

  • Initiate the firmware update in your hub (if this functionality is supported)
  • Firmware update in progress: green, yellow, and red flashing in sequence and beeping 
  • After the firmware update is complete, the actuator reboots and the LED indicator turns off for 2 seconds
  • 2 green flashes and beeps to indicate success
  • 3 red flashes and beeps to indicate a failed update

Questions about your ZAC36 Titan? Reach out to us!

Feedback
3 out of 3 found this helpful

Have you tried our virtual assistant chatbot? This AI tool can help you find answers from thousands of articles in our Knowledge Base quickly. Find it in the bottom righthand corner of the page.

Need more help? Our friendly team is ready to help you with any questions or concerns you may have about Zooz devices. Click here to submit a support ticket.

Are your devices registered? Extended warranty and firmware access is available for registered Zooz customers. Click here to submit your registration form.

Find the latest Zooz devices and great Z-Wave deals at The Smartest House.
 
scroll to top icon