On/off status not displaying properly, scenes failing to run or reports not being received? This can point to a connectivity issue between the ZEN20 and your HomeSeer hub. Check out the troubleshooting steps below if your ZEN20 Power Strip is unavailable, shows as offline, or is unresponsive to commands via HomeSeer.

When connected to the hub through the standard Z-Wave mesh, the ZEN20 Power Strip has a range of up to 300 feet line of sight (or up to 1 mile with Long Range enabled). However, interference from large furniture, thick walls, and metal elements can reduce this range. The actual range depends on your home's specific structure and the strength of your mesh network. If you experience connectivity issues, we recommend first healing your HomeSeer network, also known as rebuilding routes. This function refreshes the connections between your hub and devices, allowing the hub to find the most efficient route to each device.

 

  1. Click on the on the upper left hand side of the interface.Plugins drop-down menu 

  2. Click on . Z-Wave Plus

  3. Select .Advanced Functions

  4. From the first drop down menu, select the name of the Z-wave network you are repairing/rebuilding routes.

  5. From the second drop down menu, select Rebuild All Routes.

  6. Click The network repair will occur; remember to manually wake any battery powered devices to complete the rebuild.Continue. 

If rebuilding the routes didn't help get your ZEN20 back online, here are some other things that may help:

  1. Try excluding and re-including the plug directly from its target location. It could be that the hub hasn't found the most efficient communication route to the plug and excluding it will help the hub devise a better route of communication to the ZEN20.

  2. Add a Z-Wave signal repeater in a location between the plug and hub. This can be any Z-Wave device that doesn't rely on battery power. If the issue is caused by interference or range, a signal repeater can help strengthen and stabilize connectivity. After adding the repeater, it's a good idea to rebuild routes once more. 

  3. Bring the ZEN20 closer to the hub, removing and re-adding the plug in the new spot. If the ZEN20 includes successfully, stays connected, and is responsive to remote commands, it's possible the previous location was out of the hub's range or there is too much interference in that particular area. 

If none of the above troubleshooting steps solve the problem, please let us know! We're always here to help!

Feedback
0 out of 0 found this helpful

Have you tried our virtual assistant chatbot? This AI tool can help you find answers from thousands of articles in our Knowledge Base quickly. Find it in the bottom righthand corner of the page.

Need more help? Our friendly team is ready to help you with any questions or concerns you may have about Zooz devices. Click here to submit a support ticket.

Are your devices registered? Extended warranty and firmware access is available for registered Zooz customers. Click here to submit your registration form.

Find the latest Zooz devices and great Z-Wave deals at The Smartest House.
 
scroll to top icon