Here is a list of the changes and updates we made to the ZEN16 MultiRelay so far.
VER. 1.0 (released 12/2019)
Original release.
Hardware:
- Did NOT include USB C cable
Firmware: 1.0
-
3 switch types to choose from (on/off toggle fixed to position, on/off toggle regular, momentary)
-
Built-in timer available in minutes only
VER. 1.01 (released 1/2020 as OTA file only)
Firmware: 1.01
-
Added the ability to change timer unit to seconds or hours
VER. 1.02
Hardware:
- Added USB C cable to box
Firmware: 1.02
- Added additional switch type: garage door mode (acts as momentary contact for wall switch AND Z-Wave control, no need to set-up timers individually)
- Added an additional mode for disabled manual control behavior (for the relay to still report on/off if the Sw input is triggered manually)
VER. 1.03
Firmware: 1.03
- Added the ability to change relays to NC (normally closed) and customize on/off reports based on the switch / relay position
- Added DC motor control mode which prevents R1 and R2 to be turned on at the same time
VER. 1.04
Firmware: 1.04
- Fixed status reporting behavior for polling commands
- Fixed a bug with relay behavior after a power outage (the relays didn't turn back on after the outage if they were individually triggered prior to the outage)
VER. 1.10
Firmware: 1.10
- Addressed issues with secure inclusion that affected the pairing process on select platforms.
VER. 1.20
Firmware: 1.20
- Addressed issues with reporting when relays are triggered via Sw inputs when Multirelay is added with S2U security on select platforms.
VER. 2.0 (released 06/2023)
Hardware:
- 700 Series Z-Wave chip for extra range and reliable communication
Firmware: 2.00
- Added 7 input types to choose from to monitor separately from the output control. See all advanced parameters here.
- Added additional switch type: garage door mode for relay + open/close type for input. See all advanced parameters here.
- Added Parameters 25, 26, and 27 to reverse the reporting on sensor inputs. See all advanced parameters here.
- Separate inputs from outputs when parameters 12,13, and 14 are set to value 0. See all advanced parameters here.
Firmware: 2.10 (released 05/2024)
- Added a new value for parameter 24 "DC Motor mode" for the application with 3-speed fans/motors, so that only 1 relay can be turned on at the same time
- Fixed setting bug: you can now set any value for parameters 2, 3, and 4 (input type) when parameter 24 (DC motor mode) is set to value 1 or 2 (enabled).
- Fixed a bug with the auto turn-off timer for R1, R2, and R3 whenever parameters 12, 13, and 14 are changed from value 1 to 0. Parameters 2, 3, and 4 values 0-10 were affected.
- Added new settings to set input trigger duration (parameters 28, 29, and 30, see all settings here)
- Added new setting to assign fixed on or off actions to inputs (parameter 31, see all settings here)
Your MultiRelay can be updated via OTA firmware updates. You can access all firmware files here after you register your product and create an account here. Questions? Just reach out to our tech support team.