You can access all of the ZEN21's advanced features, like an auto timer and on/off status after power failure.
This is product is discontinued and replaced with ZEN71.
Follow the steps below to change any setting for your ZEN21 in your Vera interface; we took on/off status recovery as an example, but the same steps apply for any other setting. The full details for all parameters can be found here. Unfortunately, Vera doesn't currently support the scene control (multi-tap) functionality of our switches.
How to change an advanced setting parameter for your ZEN21 in Vera:
- Open your Vera online interface (the browser dashboard, not the app)
- Click on the Zooz ZEN21 On/Off Switch
- Go to Device Options
- Click on Add configuration settings
- Put in the following to change on/off status after power failure:
- Variable = 8
- Data Size = 1 byte dec
- Desired Value = [0 – forced to OFF (regardless of state prior to power outage); 1 – forced to ON (regardless of state prior to power outage); 2 – remembers and restores on/off status after power failure (default)]
- Click on Save Changes
Questions about the ZEN21 or any of its advanced options? Contact us!